


Volume 20 No 10 (2022)
Download PDF
Diagnostic Accuracy of FNAC when compared to Histopathology in various lesions in a Tertiary Care Centre
Dr. Mudasir Rashid, Dr. Arvind Khajuria
Abstract
FNAC is an established rapid, cost effective minimally invasive and highly accurate method for
diagnosing lesions in different organs, both superficial and deep. The diagnostic accuracy of FNAC
depend upon several factors which include site and type of lesions, experience of aspirator, quality of
smear and diagnostic skills of cytopathologist. Study of FNAC diagnosis and comparison with subsequent
histopathological diagnosis improves the skills of understanding and interpretation of cytological details
of the FNAC. A cross sectional hospital based study was carried out on 50 selected cases with FNAC
aspiration. The histological diagnosis was correlated with its subsequent histopathology to assess the
diagnostic accuracy of FNAC.
The diagnostic accuracy rate in breast lesions was found to be 91.4 percent and specificity of tumour
was found to be 100 percent. In lymphnodes FNAC was found out to be 96 percent sensitivity 100
percent and specificity 93.75 percent. The overall diagnostic accuracy in thyroid lesions was 87.5 percent
with sensitivity 100 percent and specificity 85.7 percent. While as the diagnostic accuracy in soft tissue
lesions and salivary glands was 83.3 percent and 100 percent respectively. The diagnostic accuracy of
FNAC of skin nodule was found out to be 100 percent.
Our study could achieve 93 percent diagnostic accuracy of FNAC with specificity 94.93 percent and
sensitivity 85.71 percent. However, we found that vascular lesions are difficult to be diagnosed on FNAC
as only blood aspiration is possible. Overall, we found that FNAC has high accuracy when used together
with clinical and radiological information
Keywords
FNAC, diagnostic accuracy, thyroid lesions, breast lesions, lymphnodes, soft tissue lesions, salivary glands.
Copyright
Copyright © Neuroquantology
Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
Articles published in the Neuroquantology are available under Creative Commons Attribution Non-Commercial No Derivatives Licence (CC BY-NC-ND 4.0). Authors retain copyright in their work and grant IJECSE right of first publication under CC BY-NC-ND 4.0. Users have the right to read, download, copy, distribute, print, search, or link to the full texts of articles in this journal, and to use them for any other lawful purpose.