Volume 20 No 10 (2022)
 Download PDF
Estimation of Naratriptan Hydrochloride by using RP-HPLC method
Swati Lade, Nirmal Shah , Sushil Burle
Abstract
Naratriptan Hydrochloride is a 5-hydroxytryptamine 1 receptor subtype agonist used to treat migraines. Naratriptan was purified using an RP-HPLC technique using a 25:75 v/v potassium dihydrogen phosphate (KH2PO4):acetonitrile mobile phase. The detecting wavelength was 224nm, and the flow rate was kept constant at 1.0 ml/min. The linearity of the suggested Naratriptan technique was tested in the 5-25mg/ml range. The quantitation limit was 0.75 mg/ml, and the detection limit was 0.25 mg/ml. The % recovery of nariptan ranged from 98.22 to 99.04. The percent R.S.D. value for intraday precision research was 1% and 2% for interday precision study, demonstrating that the procedure was exact enough. The validation investigations were conducted in compliance with ICH guidelines.The approach was discovered to be particular, linear, exact, accurate, and resilient
Keywords
Naratriptan; HPLC; Assay, Migraine
Copyright
Copyright © Neuroquantology

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

Articles published in the Neuroquantology are available under Creative Commons Attribution Non-Commercial No Derivatives Licence (CC BY-NC-ND 4.0). Authors retain copyright in their work and grant IJECSE right of first publication under CC BY-NC-ND 4.0. Users have the right to read, download, copy, distribute, print, search, or link to the full texts of articles in this journal, and to use them for any other lawful purpose.